Input Signal Parameters:
- Current Signal (mA):
- Range: -24~24mA
- Accuracy: 0.03%
- SR: 0.001mA
- IR: 10u03a9
- Voltage Signal (V):
- Range: -30~30V
- Accuracy: 0.03%
- SR: 0.001V
- IR: 2Mu03a9
- ±5(V):
- Range: -5~5V
- Accuracy: 0.03%
- SR: 0.0001V
- IR: 2Mu03a9
- Frequency (Hz):
- Range: 0~50000Hz
- Accuracy: 0.03%
- SR: Auto Range
- IR: 100K
- Millivolt (mV):
- Range: -110~110mV
- Accuracy: 0.03%
- SR: 0.01mV
- IR: 20Mu03a9
- Thermocouple Types (TC):
- TC-S Range: 0~1760°C, Accuracy: 0.10%, SR: 1°C, IR: 20Mu03a9
- TC-B Range: 0~1810°C, Accuracy: 0.20%, SR: 1°C, IR: 20Mu03a9
- TC-E Range: 0~990°C, Accuracy: 0.10%, SR: 1°C, IR: 20Mu03a9
- TC-K Range: 0~1320°C, Accuracy: 0.10%, SR: 1°C, IR: 20Mu03a9
- TC-R Range: 0~1760°C, Accuracy: 0.10%, SR: 1°C, IR: 20Mu03a9
- TC-J Range: 0~1190°C, Accuracy: 0.10%, SR: 1°C, IR: 20Mu03a9
- TC-T Range: 0~390°C, Accuracy: 0.10%, SR: 1°C, IR: 20Mu03a9
- TC-N Range: 0~1290°C, Accuracy: 0.10%, SR: 1°C, IR: 20Mu03a9
- Resistance Input:
- Range: 0~400Ku03a9
- Accuracy: 0.10%
- SR: Auto Range
Output Signal Parameters:
- Current Signal (mA):
- Range: 0~23mA
- Accuracy: 0.03%
- SR: 0.001mA
- IR: 100u03a9
- Voltage Signal (V):
- Range: 0~23V
- Accuracy: 0.03%
- SR: 0.001V
- IR: 2Ku03a9
- Low Voltage (V):
- Range: -0.22~2.4V
- Accuracy: 0.03%
- SR: 0.1mV
- IR: 2Ku03a9
- Millivolt (mV):
- Range: -10~110mV
- Accuracy: 0.03%
- SR: 0.01mV
- IR: 2Ku03a9
- Passive Signal (XMT):
- Range: 0~24mA
- Accuracy: 0.03%
- SR: 0.001mA
- IR: 100u03a9
- 24V Circuit Detection:
- Range: 0~24mA
- Accuracy: 0.05%
- SR: 0.001mA
- IR: 100u03a9
- Frequency (Hz):
- Range: 0~100KHz
- Accuracy: 0.03%
- SR: 0.001Hz~1Hz
- IR: 100K
- Thermocouple Types (TC):
- TC-S Range: 0~1760°C, Accuracy: 0.10%, SR: 1°C, IR: 2K
- TC-B Range: 0~1810°C, Accuracy: 0.10%, SR: 1°C, IR: 2K
- TC-R Range: 0~1760°C, Accuracy: 0.10%, SR: 1°C, IR: 2K
- TC-E Range: 0~990°C, Accuracy: 0.10%, SR: 0.1°C, IR: 2K
- TC-K Range: 0~1320°C, Accuracy: 0.10%, SR: 0.1°C, IR: 2K
- TC-J Range: 0~1190°C, Accuracy: 0.10%, SR: 0.1°C, IR: 2K
- TC-T Range: 0~390°C, Accuracy: 0.10%, SR: 0.1°C, IR: 2K
- TC-N Range: 0~1290°C, Accuracy: 0.10%, SR: 0.1°C, IR: 2K
- Resistance Output:
- Range: 0~4000u03a9
- Accuracy: 0.10%
- SR: 0.1u03a9
Features:
1. Versatile Signal Types:
This multifunctional device supports a wide variety of signal types including voltage, current, frequency, resistance, and thermocouples, making it a one-stop solution for numerous applications.
2. High Accuracy:
With an impressive accuracy of 0.03% for most signal types, this device ensures precise measurements and outputs, which is critical for high-stakes environments.
3. Easy Simultaneous Measurement and Output:
Offering both simplex and duplex modes, it allows for simultaneous measurement and output, enhancing workflow efficiency and simplifying complex tasks.
4. Wide Temperature Range:
Supports an extensive temperature range across various thermocouple types, accommodating industries that require strict thermal regulation and monitoring.
5. User-Friendly Interface:
The intuitive user interface makes this device straightforward to operate, reducing training time and improving operational productivity.
Package Included:
1 x MR9271PRO Signal Generator
4 x Test Cable Set
1 x Power Adapter
1 x USB Cable
4 x Alligator Clips (Yellow, Blue, Black, Red)
1 x Alligator Clip Cable
1 x 3.5mm to Terminal Connector
1 x Carrying Case