Home>mall>Tools, Industrial & Scientific
0Halaýar

AAI ORIGINAL English Verison N1201SA N1201SA+ 34.375MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester

4.4
★★★★★
320
$109.99 / $134.19
  • *Name:

  • *Email:

  • *Phone:

  • *Quantity:

  • *Content:

  • Attachment:

    Supports JPG, JPEG, PNG, PDF, EXCEL, WORD, RAR, ZIP, 7z formats

$93.99 / $134.19

Ygtybarly howpsuz töleg

Mugt sowgat
Islendik satyn almagyňyzda mugt sowgat
Iberiş syýasaty
$9.9-dan ýokary sargytlarda mugt standart iberiş
Yzyna gaýtarma syýasaty
Harytlar alynan günden 40 gün içinde yzyna gaýtarylýar. Yörite harytlar yzyna gaýtarylýanok. E-sowgat kartoçkasy bilen satyn alynan harytlar diňe çalşylýar; yzyna gaýtarylýanok.

Mugt Sowgat

Roymall-a hoş geldiňiz, premium sowgatlar satyn almak üçin hünärmen web sahypaňyz. Goldawyňyzy gymmatlandyrýarys we her sargydyňyzda mugt sowgat hödürleýäris.

Iberiş Syýasaty

Sargytlaryňyz 2-5 iş gününde eltip beriler. $9.9-dan ýokary sargytlarda mugt iberiş.

1. Yzyna Gaýtarma Syýasaty

Harytlar 40 gün içinde yzyna gaýtarylýar. Yörite harytlar yzyna gaýtarylýanok.

2.Yzyna Töleg Syýasaty

Töleg original töleg usuly bilen yzyna gaýtarylýar.
Description:
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration

The default boot into single-point measurement interface.

Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.



Startup and shutdown:
Hold down the CTRL key off press the power switch button.

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down



Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.

2, try to use good quality RF cable and connectors.

3, calibrated cable marked to the next may not need to calibrate and direct use.

4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.

5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.

6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis



Specification:
working currency: 140MHz~2700MHz

stepped frequency: 1kHz

Display: 2.4inch TFT

resolution: 320*240(QVGA)

battery: 2000mAH(7.4Wh)

power consumption: <1.5W

charge current: 400mA

charge port: USB

Auto power off can be set 5-60minutes



Measured parameters:
resistence reactance standing wave s11

resolution ratio: 4 number

frequency accuracy: about 5ppm

Connector: SMA-K

Measurement range:
impedance: 0.1~1000

standing wave: 1.000~65

s11(dB): 0dB~-60dB

Working temperature: 0~40 degree



Package included:
1 x Original N1201SA Antenna Analyzer Meter

1 x English User Manual

Description:
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration

The default boot into single-point measurement interface.

Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.



Startup and shutdown:
Hold down the CTRL key off press the power switch button.

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down



Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.

2, try to use good quality RF cable and connectors.

3, calibrated cable marked to the next may not need to calibrate and direct use.

4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.

5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.

6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis



Specification:
working currency: 140MHz~2700MHz

stepped frequency: 1kHz

Display: 2.4inch TFT

resolution: 320*240(QVGA)

battery: 2000mAH(7.4Wh)

power consumption: <1.5W

charge current: 400mA

charge port: USB

Auto power off can be set 5-60minutes



Measured parameters:
resistence reactance standing wave s11

resolution ratio: 4 number

frequency accuracy: about 5ppm

Connector: SMA-K

Measurement range:
impedance: 0.1~1000

standing wave: 1.000~65

s11(dB): 0dB~-60dB

Working temperature: 0~40 degree



Package included:
1 x Original N1201SA Antenna Analyzer Meter

1 x English User Manual

Sebetim Sebet (22)
Halananlarym Halananlar (0)